Very Hot Topic (More than 500 Replies) Ponte H per inverter 3KW 24V (Read 559899 times)
cavallino
God Member
*****
Offline


--------

Posts: 1234
Gender: Male
Zodiac sign: Sagittarius
Re: Ponte H per inverter 3KW 24V
Reply #60 - 02.07.16 at 21:26:41
Print Post  
In ogni caso ti faccio faccio vedere lo schemino della mia idea.
  

ponte_h_001.png ( 39 KB | Downloads )
ponte_h_001.png

Ciao a tutti
Back to top
 
IP Logged
 
ElettroshockNow
Forum Administrator
*****
Offline


yottawatt

Posts: 3920
Location: Roma
Gender: Male
Zodiac sign: Gemini
Re: Ponte H per inverter 3KW 24V
Reply #61 - 02.07.16 at 21:48:15
Print Post  
Il problema è trovare dei canali P così potenti .... Cry
  

Il Tempo non lo vede nessuno,il lavoro lo vedono tutti (Mamma)
Impara a rubare con gli occhi (Papà)
Back to top
YouTube  
IP Logged
 
cavallino
God Member
*****
Offline


--------

Posts: 1234
Gender: Male
Zodiac sign: Sagittarius
Re: Ponte H per inverter 3KW 24V
Reply #62 - 02.07.16 at 22:07:45
Print Post  
Su questo condivido pure io sono difficile,ma ci sono,basta cercare i complimentare.
  

Ciao a tutti
Back to top
 
IP Logged
 
cavallino
God Member
*****
Offline


--------

Posts: 1234
Gender: Male
Zodiac sign: Sagittarius
Re: Ponte H per inverter 3KW 24V
Reply #63 - 02.07.16 at 22:23:55
Print Post  
Elettro se hai tempo vai a leggere i dati di questo
mosfet IRFP4468,e alla fine costa pure poco  Wink
  

Ciao a tutti
Back to top
 
IP Logged
 
RFBurns
New Member
*
Offline


New EALab Member

Posts: 41
Location: Australia
Gender: Male
Re: Ponte H per inverter 3KW 24V
Reply #64 - 03.07.16 at 01:19:41
Print Post  
ElettroshockNow wrote on 02.07.16 at 19:09:17:
RFBurns wrote on 30.06.16 at 08:16:51:
A couple of other ideas for you

One heat sink no cuts this is s 12v version
this is not my board but this design/board can be used from 12v to 48v

.... immagini aggiornate .... fantastiche e bellissima configurazione.

Potenza e mosfet ?


This is 3KW 12v IRFB4110 (very cheap) Smiley
  

Get with it, Get over it , Get on with it, Or leave

Cheap and reliable wont be fast.
Cheap and fast wont be reliable.
Reliable and fast wont be cheap.
Back to top
 
IP Logged
 
xardas
God Member
*****
Offline


La resistenza è una condizione
mentale

Posts: 746
Gender: Male
Zodiac sign: Taurus
Re: Ponte H per inverter 3KW 24V
Reply #65 - 03.07.16 at 08:07:17
Print Post  
cavallino wrote on 02.07.16 at 20:19:25:
Da tenere presente che sul mezzo ponte deve circolare una corrente di circa 70 ampere e altri 70 sul rimanente mezzo ponte.

Ripeto da parte mia sono contrario ad assemblare  il mosfet sul pcb,andavo direttamente sulle alette di raffreddamento,e se era possibile anziché' usavo dei mosfet canale N potete usare anche il canale  P dato che state usando dei draw per pilotare il ponte.cosi facendo su una ramo avete la prima uscita e sul secondo ramo la seconda uscita,cosi  potete usare la stessa aletta di raffreddamento come conduttore senza usare nessun isolamento dei mosfet.



Su questo condivido pienamente con te...

Sul mio Inverter comprato da ebay, ci sono gli stessi accorgimenti ciò evita di isolare con mica i mosfet e inoltre si ha secondo me una efficenza un pò superiore giacchè tutto il corpo di drain è paralellato con gli altri dello stesso canale...

Ottimo Cavallino Wink
  
Back to top
 
IP Logged
 
Bridge
Senior Member
****
Offline


New EALab Member

Posts: 282
Re: Ponte H per inverter 3KW 24V
Reply #66 - 03.07.16 at 09:41:10
Print Post  
RFBurns wrote on 03.07.16 at 01:19:41:
This is 3KW 12v IRFB4110 (very cheap) Smiley

Uhhhh!, ....3kW @12V= 250A ....."very terrible current"; very hard to manage.-
Which DC source are you using?.-
  
Back to top
 
IP Logged
 
cavallino
God Member
*****
Offline


--------

Posts: 1234
Gender: Male
Zodiac sign: Sagittarius
Re: Ponte H per inverter 3KW 24V
Reply #67 - 03.07.16 at 10:02:09
Print Post  
Bridge wrote on 03.07.16 at 09:41:10:
RFBurns wrote on 03.07.16 at 01:19:41:
This is 3KW 12v IRFB4110 (very cheap) Smiley

Uhhhh!, ....3kW @12V= 250A ....."very terrible current"; very hard to manage.-
Which DC source are you using?.-


Secondo me sono troppi 250 ampere per poteri controllare,già con 160 ampere a 24 volt mi viene difficile poterli gestire,figuriamoci il doppio.
Stiamo parlando di una potenza di 250 x 12=3000 WATT,ci vogliono cavi da 75 mmq come minimo,e' una bella impresa,auguri. Smiley

I think there are too many 250 amps for power control, already with 160 amps at 24 volts it is very difficult to manage them, let alone twice.
We are talking about a power of 250 x 12 = 3000 WATT, it takes from 75 sq mm cables at a minimum, and 'beautiful company, wishes.

GOOGLE traduttore,traduce male,bisogna aggiornalo un pochettino  Grin
  

Ciao a tutti
Back to top
 
IP Logged
 
RFBurns
New Member
*
Offline


New EALab Member

Posts: 41
Location: Australia
Gender: Male
Re: Ponte H per inverter 3KW 24V
Reply #68 - 03.07.16 at 10:30:30
Print Post  
Yes I agree 250A is not good  Cry ; 75 sq mm is only 10mm cable. See the picture it is tested with 8mm . This not Ideal and made for a particular function . I think < 48v is not the best . The translator seems to be working O.K?
  

Get with it, Get over it , Get on with it, Or leave

Cheap and reliable wont be fast.
Cheap and fast wont be reliable.
Reliable and fast wont be cheap.
Back to top
 
IP Logged
 
Bridge
Senior Member
****
Offline


New EALab Member

Posts: 282
Re: Ponte H per inverter 3KW 24V
Reply #69 - 03.07.16 at 11:42:02
Print Post  
In addition to the big cable section is "fundamental" do not forget to handle the "ever-present contact resistance" in this context, such as bolts, connections, etc,  and always a source of trouble.-

Oltre alla grande sezione del cavo è "fondamentale" non dimenticare di gestire la "resistenza di contatto" sempre presente in questo contesto, come  bulloni, connessioni, ecc, e sempre fonte di guai.
  
Back to top
 
IP Logged
 
cavallino
God Member
*****
Offline


--------

Posts: 1234
Gender: Male
Zodiac sign: Sagittarius
Re: Ponte H per inverter 3KW 24V
Reply #70 - 03.07.16 at 11:49:03
Print Post  
RFBurns wrote on 03.07.16 at 10:30:30:
Yes I agree 250A is not good  Cry ; 75 sq mm is only 10mm cable. See the picture it is tested with 8mm . This not Ideal and made for a particular function . I think < 48v is not the best . The translator seems to be working O.K?


Sì sono d'accordo 250A non è buona Cry; 75 mmq è solo 10 millimetri cavo. Vedere l'immagine che viene testato con 8 mm. Questo non ideale e realizzato per una particolare funzione. Credo <48V non è il migliore. Il traduttore sembra funzionare O.K?

Se puoi andare a 48 volt sarebbe una cosa ideale,e cosi facendo scendi di parecchio come amperaggio e si può gestire meglio,cosi eviti il riscaldamento di tutto il complesso
  

Ciao a tutti
Back to top
 
IP Logged
 
ElettroshockNow
Forum Administrator
*****
Offline


yottawatt

Posts: 3920
Location: Roma
Gender: Male
Zodiac sign: Gemini
Re: Ponte H per inverter 3KW 24V
Reply #71 - 03.07.16 at 12:17:30
Print Post  
Il ponte che stò provando a realizzare potrà gestire anche inverter 60V o 72V  Wink ...

12V personalmente non lo prendo in considerazione è veramente una pazzia ....

Come dice Bridge ....anche un solo bullone non serrato bene può portare alla fusione di tutto  Cheesy.

Ordinati i mic4605 .... Sad
Ahimè solo ora noto che nella versione SOIC non è presente il Pin enable !!!!
Come porre rimedio ?

Dallo schema di principio sembra che la protezione undervoltage della VDD porta entrambe le uscite a low .

Forse sfruttero proprio questa caratteristica per la protezione nativa per sovra assorbimento ...
  

UnderVoltage_MIC4605.jpg ( 113 KB | Downloads )
UnderVoltage_MIC4605.jpg

Il Tempo non lo vede nessuno,il lavoro lo vedono tutti (Mamma)
Impara a rubare con gli occhi (Papà)
Back to top
YouTube  
IP Logged
 
ElettroshockNow
Forum Administrator
*****
Offline


yottawatt

Posts: 3920
Location: Roma
Gender: Male
Zodiac sign: Gemini
Re: Ponte H per inverter 3KW 24V
Reply #72 - 03.07.16 at 12:26:58
Print Post  
Un'altro pezzettino ....
  

Full_Bridge_with_MIC4605.jpg ( 936 KB | Downloads )
Full_Bridge_with_MIC4605.jpg

Il Tempo non lo vede nessuno,il lavoro lo vedono tutti (Mamma)
Impara a rubare con gli occhi (Papà)
Back to top
YouTube  
IP Logged
 
Pinko
Senior Member
****
Offline


New EALab Member

Posts: 295
Location: Malvito
Gender: Male
Zodiac sign: Scorpio
Re: Ponte H per inverter 3KW 24V
Reply #73 - 03.07.16 at 23:40:21
Print Post  
ElettroshockNow wrote on 03.07.16 at 12:26:58:
                        Un'altro pezzettino ....
                   


Li vedo già su una schedina a pettine, o magari due. Resterebbe più spazio, magari per qualche elettrolitico in più.
  

"fatti non fummo a viver come bruti ma per seguir virtute e canoscenza"
Back to top
 
IP Logged
 
ElettroshockNow
Forum Administrator
*****
Offline


yottawatt

Posts: 3920
Location: Roma
Gender: Male
Zodiac sign: Gemini
Re: Ponte H per inverter 3KW 24V
Reply #74 - 04.07.16 at 20:20:22
Print Post  
Pinko wrote on 03.07.16 at 23:40:21:
ElettroshockNow wrote on 03.07.16 at 12:26:58:
                        Un'altro pezzettino ....
                   


Li vedo già su una schedina a pettine, o magari due. Resterebbe più spazio, magari per qualche elettrolitico in più.


Ma dai ... 16000 uF dovrebbero essere sufficienti .  Cheesy

Facciamo sempre in tempo ad allungare la scheda ...per accogliere più finali e più elettrolitici  Wink
  

Il Tempo non lo vede nessuno,il lavoro lo vedono tutti (Mamma)
Impara a rubare con gli occhi (Papà)
Back to top
YouTube  
IP Logged
 